Anderson-Negele NSL-F(R)-02
Continuous Level Sensor with Dual Probe | Food, Beverage and Dairy
Level Sensors, IO-Link
Potentiometric, continuous level measurement in metallic or plastic vessels with hygienic thread G1″ (CLEANadapt, Tri-Clamp), compact version.
- Optimized resource efficiency through precise measurement even for demanding applications with foam, pasty or highly adhesive media.
- Flex-Hybrid: Digital IO-Link and analogue 4…20 mA parallel.
- Extremely fast response time < 100 ms for filling processes.
- For non-metallic vessels from 200 mm to 1500 mm height.
- Dual probe version especially for use in plastic vessels up to 1500 mm height.
- Hygienic alternative to float sensors due to easily sterilisable installation solution.
- Ideal for adhesive and pasty media.
- Minimum product conductivity typically 50 μS/cm.
- Installation in vessels at the top, the side or from below.
- Modular design: configurable from the low-cost basic version to the high-end model.
Benefits in production processes
For efficient production processes, continuous, precise monitoring of the filling level of feed tanks, storage tanks or fillers is essential. The flexible, modular level sensor NSL-F with its potentiometric measuring principle offers a reliable and precise application even with difficult to measure media and with demanding applications such as:
- Strongly or differently foaming media.
- Pasty media or media adhering to the measuring rod.
- Pressurized tanks.
- Fast level changes, e.g. during filling processes.
- Non-metallic tanks.
- Different media in one tank.
- Tank shapes with restricted installation access.
- Production environments with high mechanical or Chemical stress (e.g. cleaning agents).
- Maximum resource efficiency due to precise measurement even with demanding media: Even with foam or with the measuring rod coated by pasty or strongly adhesive media, the measuring accuracy is <1% of the rod length.
- Ready for industry 4.0: digital IO-Link interface and analog 4…20 mA data transmission in parallel.
- Ideal for metallic, non-metallic and pressurized tanks due to rod length from 50 mm to 3 m, installation from below, above or from the side and optional versions.
- Extremely fast response time < 100 ms for precise dosing monitoring, e.g. for filling systems.
- Automatic adjustment to media, no adaptation required with alternating media in one tank.
- Hygienic alternative to float sensors due to easily sterilizable installation solution.
- Robust construction made entirely of stainless steel.